Archive
Kaseya and Safe mode
One of the things that I have always loved is playing with computers, I love to fix them and figure out what is wrong with them and sometimes you need to use safe mode to do it.
Well working with Windows 7 is no different but for those of us who use Kaseya to manage our client sites that usually means a truck roll. Well thanks to a little registry magic – you don’t need to run out to the site any more (DANGER – WILL ROBINSON – DANGER, this is not for the faint at heart).
I wrote a couple of little procedures that can be used to change the boot editor on your Vista/7/2008 system to boot into safe mode. The trick was to add the remote control service to start while in safe mode (a clever little registry hack).
You can reboot your machine with the procedure to start in safe mode, do what you need to do like remove drivers, etc. and then run another procedure to run it again in normal mode.
Drop me a line and I can share how I did it with you.
Using Kaseya to deploy LogMeIn
Sometimes the VNC connection with Liveconnect just won’t work – probably due to poor bandwidth or maybe a plugin issue so I wanted to document a simple process of using Kaseya to deploy the free/paid version of LogMeIn to your agents so you have another method of connecting remotely.
I created a script that will download a customized version of LogMeIn and run it as the system to silently install. You can run it as a procedure to install on your agents which can run on the bandwidth challenged systems.
First you have to create a customized package using your LogMeIn account and download the executable version (this process is outside the scope of this document).
Next you use the script (above) to send the file, wait for it to be downloaded, run the installer, delete the install file and update the procedure log (we added a pause to wait for the installer to complete before we try to delete the file).
Finally you upload it to your Kaseya server and modify the script to pull the new customized LogMeIn file down to your agents and that is it. No more asking clients to run remote control programs so you can connect – if the machine has a Kasey agent on it then you can run this procedure to install LogMeIn.
You can use Kaseya procedures to so almost anything – we run SQL scripts, batchfiles, WMI scripts, the list is almost endless. If you have an idea for a script or have other scripts that you would like to share – feel free to comment below.
I hope you find Kaseya as powerful as I do and learn how to make the power of Kaseya work for you.
Using VPro with the Kaseya Portal
My Observations of the VPro feature in Kaseya. If you have a machine and would like to enable the VPro feature then review my musings and follow the steps at the end of my post. If you need some help you can contact me and I will review it with you.
(You must be onsite in order to activate this – you will also need a USB key)
I wanted to detail my experience with Kaseya and the VPro feature within it. If you are like me, you might have heard of the feature that Intel has put into their CPUs but that might be all.
I am familiar with remote features like Drac, ILO, etc. in servers but the idea of remote controlling a workstation is so exciting that it opens all sorts of thoughts surrounding management without having to be in front of the keyboard. I especially love the ability of running a disk management tool to help maintain or even fix hard drives that are about to go bad. These tools can run for days and arriving to load it once and asking a local user to tell you when it finishes isn’t always convenient.
Starting with version 6.x, VPro has VNC based firmware installed in the chip – it only needs to be activated in the BIOS or by a special thumb drive – This is where the Intel Activator Wizard comes in. You can configure a standalone password for the AMT to be used by remote control and for any other AMT events. Failing to do so will allow you to connect but the screen is prompting the user for a code that is not visible when you are remoted in. In some cases I have seen versions that cannot be enabled remotely when you detect and then try to enable VPro on certain versions.
You need to have the Intel Management drivers loaded on a machine that has the Kaseya agent installed to be able to detect/enable VPro and it comes from the factory disabled. If the drivers are loaded on an OS and it is running then you can detect and perhaps enable it remotely using Kaseya. The connection topology starts by setting up a vpro proxy (this should be a publically available IP – maybe even one to one NAT) that should be available on the same subnet as the machines you are using with vpro. You map a port through to that vpro proxy machine and it then tries to open the connection to the VPro system on your behalf. You can use any port number you wish – it only requires one however you can only remote one machine at a time.
If you are able to connect through your proxy you may get a screen that asks for a 6 digit passcode. This is the user consent page – it will be asking the user for his/her consent while you try 3 times to ‘guess’ the password. This can be disabled when you use the SCS from above. If you have mistakenly provisioned it using the Kaseya portal you cannot use the AMT configuration utility again – it will state nothing to do. You must disable it in the Kaseya portal and then run the AMT program on a thumb drive on the machine you wish to reprovision in order to have control again.
You can download a program called VNC Viewer Plus to verify the connection to the AMT. You should be able to login as admin and use the password you set in the AMT configuration like the picture (attached picture 1).
You must have the ME drivers already installed to use this utility. If you need the Management drivers (your OS did not already have them installed) you should download them from Intel.
The steps I used to activate VPro are as follows;
- Use Cntrl + P to access the MEBX bios when booting up your PC.
- The default password is admin – Set the password to something you can use (you must use a complex password and the remote KVM will only accept 8 characters so please use something similar to p&ssw0rd)
- Boot the computer and insert the thumb drive with the AMT utility expanded onto the drive (http://software.intel.com/sites/default/files/m/d/4/1/d/8/IntelAMT_config_utility_Rev0.5.0.3.zip)
- Run the Activatorscript as Admin and set the password (again if you do not want/need to change it) then enable the following (see attached picture 2)
- After you save the config onto the thumb drive you can reboot the machine with the drive still in it. You should see a screen asking if you want to update the provisioning of the ME (or something similar)
- After choosing ‘Yes’ your AMT should now be enabled in the Kaseya portal.
Want more info?
Pages
Archives
- August 2022
- July 2022
- June 2022
- May 2022
- April 2022
- February 2022
- January 2022
- July 2020
- June 2020
- May 2020
- April 2020
- March 2020
- February 2020
- December 2019
- November 2019
- October 2019
- September 2019
- August 2019
- July 2019
- May 2019
- March 2019
- February 2019
- December 2018
- October 2018
- September 2018
- August 2018
- July 2018
- April 2018
- February 2018
- December 2016
- November 2016
- October 2016
- April 2016
- February 2016
- December 2015
- October 2015
- September 2015
- August 2015
- July 2015
- June 2015
- May 2015
- March 2015
- February 2015
- January 2015
- May 2014
- November 2013
- September 2013
- June 2013
- April 2013
- January 2013
- October 2012
- September 2012
- April 2012
- March 2012
- February 2012
- January 2012
- September 2011
- August 2011
- July 2011
- June 2011